UL 11028 12 AWG 65 Strand 105C 600V – Tinned Copper

Specifications

Style

Apprx LBS/MFT

Conductor Stranding

Nominal Insulation Thickness(in)

Nominal Outside Diameter(in)

Maximum Temperature Rating

Minimum Temperature Rating

Gauge

Conductor

Insulation

Voltage Rating

Bulk Quantity Discount

Discounted bulk price reflected when added to cart

SKU: W110281265-T Categories: , , ,
Bulk Quantity Price
  500-999 1000-4999 5000+
Blue $1.42 $1.34 $1.25
Violet $1.49 $1.41 $1.32

COLOR & QUANTITY SELECTION

For custom wire striping or Out of Stock Lead Times. Call 562-808-0800

Min/Mult: 250/50

ImageNamePriceStockBuy
UL 11028 12 AWG 65 Strand 105C 600V - Tinned Copper - Blue
UL 11028 12 AWG 65 Strand 105C 600V - Tinned Copper - Blue$1.67

400 in stock

UL 11028 12 AWG 65 Strand 105C 600V - Tinned Copper - Violet
UL 11028 12 AWG 65 Strand 105C 600V - Tinned Copper - Violet$1.76

400 in stock

PRODUCT INFORMATION

National Electric USA‘s quality UL 11028 12 AWG 65 Strand Tinned Copper 105C 600V wire is a part of the mPPE insulated, hook-up & lead wire product line. Our wide range of UL 11028 12 AWG 65 Strand Tinned Copper 105C 600V wire can be seen used directly or indirectly throughout a large number of industries such as but not limited to the appliance, electronics, factory automation & robotics, heating, ventilation, air conditioning, lighting, medical, gas grill, stove, and many other industry applications. At National Electric USA, we stock and can procure several cable variations and options that may fit you application or interest you.

Can not find exactly what you’re looking for? Do not worry, we can still help you! To inquire and learn more, call us directly and speak with a customer service representative or wire and cable expert by dialing today: 562-808-0800 or emailing us directly to customerservice@z-tronix.com

APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11028 Issued:2006-05-09
Revised:2011-08-26
Style 11028 Single Conductor with extruded insulation

 

Rating 105 deg C, 600 Vac, Horizontal flame.
Conductor 40 AWG – 10 AWG, solid or stranded.
Insulation Extruded mPPE, 8 mils min average, 7 mils minimum at any point.
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring.