UL 3512 16 AWG 07 Strand 200C 600V – Tinned Copper

Specifications

Style

Gauge

Conductor

Insulation

,

Voltage Rating

Bulk Quantity Discount

Discounted bulk price reflected when added to cart

SKU: W35121607-T Categories: , ,
Bulk Quantity Price
  500-999 1000-4999 5000+
White $0.31 $0.30 $0.28
Yellow $0.31 $0.30 $0.28
Orange $0.31 $0.30 $0.28
Blue $0.31 $0.30 $0.28

COLOR & QUANTITY SELECTION

For custom wire striping or Out of Stock Lead Times. Call 562-808-0800

Min/Mult: 250/50

ImageNamePriceStockBuy
UL 3512 16 AWG 07 Strand 200C 600V - Tinned Copper - White
UL 3512 16 AWG 07 Strand 200C 600V - Tinned Copper - White$0.37

10120 in stock

UL 3512 16 AWG 07 Strand 200C 600V - Tinned Copper - Yellow
UL 3512 16 AWG 07 Strand 200C 600V - Tinned Copper - Yellow$0.37

7500 in stock

UL 3512 16 AWG 07 Strand 200C 600V - Tinned Copper - Orange
UL 3512 16 AWG 07 Strand 200C 600V - Tinned Copper - Orange$0.37

4550 in stock

UL 3512 16 AWG 07 Strand 200C 600V - Tinned Copper - Blue
UL 3512 16 AWG 07 Strand 200C 600V - Tinned Copper - Blue$0.37

12230 in stock

PRODUCT INFORMATION

National Electric USA‘s quality UL 3512 16 AWG 7 Strand Tinned Copper 200C 600V wire is a part of the silicone insulated, hook-up & lead wire product line. Our wide range of UL 3512 16 AWG 7 Strand Tinned Copper 200C 600V wire can be seen used directly or indirectly throughout a large number of industries such as but not limited to the aerospace, appliances (washer/dryer), electronics, factory automation & robotics, heating, ventilation, air conditioning, lighting, medical, gas grill (electronic ignition of gas ranges and fuel/oil burners), stove, and many other industry applications. Silicone Rubber Insulation, also known as SR, offers the advantages of insensibility to chemicals, weather resistance, non flammability in addition its zero moisture capture capabilities. At National Electric USA, we stock and can procure several cable variations and options that may fit your application or interest you.

Can not find exactly what you’re looking for? Do not worry, we can still help you! To inquire and learn more, call us directly and speak with a customer service representative or wire and cable expert by dialing today: 562-808-0800 or emailing us directly to customerservice@z-tronix.com

APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3512 Issued:1987-08-18
Revised:2015-10-13
Style 3512 Single Conductor with Extruded Insulation.

 

Rating 200 deg C, 600 Vac, Horizontal Flame.
Conductor 0.3 – 250 sq mm, solid or stranded. If tinned copper strands are used, they shall be 0.0152 in diameter or larger.
Separator Optional.
Insulation Extruded SR.
Conductor size Minimum average thickness Minimum thickness at any point
0.3-4.0 sq mm 30 mils 27 mils
4.1-9.0 sq mm 45 mils 40 mils
9.1-35.0 sq mm 60 mils 54 mils
35.1-100.0 sq mm 80 mils 76 mils
100.1-250.0 sq mm 95 mils 85 mils
Maybe applied in two layers with an intermediate glass braid (optional).
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring of appliances where totally enclosed.

UL and the UL Logo are trademarks of UL LLC © 2018